TABLE OF SPECIFICATION FOR IGLOO INVERTER UNITS |
|||
| unit specification / model | MCP 10
MCP 4F |
MCP 15
MCP 7F |
MCP 25
MCP 11F |
| scroll inverter compressor (900–7200 RPM) | • | • | • |
| compressor crankcase heater | • | • | • |
| mechanical oil separator | • | • | • |
| lamellate condenser | • | • | • |
| energy-efficient EC condenser fan | • | • | • |
| coolant tank | • | • | • |
| safety valve | • | • | • |
| coolant sight glass | • | • | • |
| thermal insulation of coolant tank | • | • | • |
| stop valve behind the coolant tank | • | • | • |
| liquid separator (suction accumulator) | • | • | • |
| low pressure transmitter | • | • | • |
| high pressure transmitter | • | • | • |
| wet steam injection system for compressor head | • | • | • |
| LP pressure switch | • | • | • |
| HP pressure switch | • | • | • |
| unit’s acoustic isolation | • | • | • |
| motherboard | • | • | • |
| PLC | • | • | • |
| menu in Polish and English | • | • | • |
| recorder of unit operation parameters | • | • | • |
| inverter compressor drive in the IGLOO Professional housing | • | • | • |
| main load switch | • | • | • |
| circuit breaker | • | • | • |
| 230V service socket | • | • | • |
| overcurrent protection of the service socket | • | • | • |
| heating module of the unit switchgear section | • | • | • |
| cooling fan of the unit switchgear section | • | • | • |
| night-work Silent algorithm | • | • | • |
| algorithm of protection against flooding | • | • | • |
| algorithm of protection against excessive pressure | • | • | • |
| algorithm of protection against excessive discharge temperature | • | • | • |
| detection and signaling of dirty condenser | • | • | • |
| protection against the effects of lack of coolant | • | • | • |
| RS485 for connection with monitoring systems | • | • | • |
| LOW bar MODE | • | • | • |
| housing made of AlZn sheet metal with prime coating equivalent to Pure White structure color | • | • | • |
| exterior lamp indicating unit operating conditions | • | • | • |
| set of stop connection valves with AVX | • | • | • |
| graphical control panel | • | • | • |
| external information panel (replaces the external indicator lamp) | O | O | O |
| plate heat-recovery exchanger–SHM system | O | O | O |
| safety kit with three-way valve | O | O | O |
| external hydromodule–ACU | O | O | O |
| possibility of connecting to redundant operation | O | O | O |
| Power Pick–function only for redundant operation | O | O | O |
| built-in BMS XWEB module | O | O | O |
| external BMS Plant Watch module | O | O | O |
| external BMS Boss module | O | O | O |
| external BMS Mini Boss module | O | O | O |
| external LTE router for BMS module | O | O | O |
| additional accessories | |||
| set with frame for wall mounting with vibro-isolators | O | O | O |
| set of suction oil siphons | O | O | O |
| set of discharge oil siphons | O | O | O |
| service panel | • | • | • |
| • | standard |
| O | option |
| – | unavailable |