The unit model should be selected according to the table below. Data developed for R404A/R507 coolant | |||||
model | Q [kW] | [°C] | Min Qcool from sum of receivers [kW] | ||
from | to | ||||
Operation range–refrigerating | MCP-10 | 1,5 | 10 | -10 | 5,0 |
MCP-15 | 2,5 | 17 | -10 | 7,5 | |
MCP-25 | 3,5 | 25 | -10 | 9,0 | |
Operation range–freezing | MCP-4F | 1 | 4 | -30 | 2,0 |
MCP-7F | 1,6 | 7 | -30 | 3,0 | |
MCP-11F | 2,5 | 10 | -30 | 4,0 |
Dimensions | MCP 10 | MCP 15 | MCP 25 | MCP 4 F | MCP 7 F | MCP 11 F |
length [mm] | 1310 | 1510 | 1510 | 1310 | 1510 | 1510 |
width [mm] | 480 | 550 | 550 | 480 | 550 | 550 |
height [mm] | 1015 | 1165 | 1915 | 1015 | 1165 | 1165 |
weight [kg] | MCP10 – 120 | MCP15 – 150 | MCP25 – 200 | MCP4F-115 | MCP7F – 140 | MCP11F –150 |
Cooling characteristics | MCP 10 | MCP 15 | MCP 25 | MCP 4 F | MCP 7 F | MCP 11 F |
Cooling capacity [kW] | 10 | 15 | 25 | 5 | 7 | 11 |
liquid pipeline connection [mm] | 12 | 16 | 18 | 22 | 22 | 28 |
gas pipeline connection [mm] | 22 | 22 | 28 | 22 | 22 | 28 |
compressor model |
Emerson* XPV0382E / Hitachi MS300 |
Hitachi MS400 | Hitachi MS500 | Hitachi MS300 | Hitachi MS400 | Hitachi MS500 |
RPM speed | 1000 – 7200 | 1000 – 7200 | 1000 – 7200 | 1000 – 7200 | 1000 – 7200 | 1000 – 7200 |
acceptable types of coolant | R404A ▪ R507A ▪ R448A ▪ R449A ▪ R407F** ▪ R407A** R407H** ▪ R452A ▪ R407C** | |||||
filling oil separator with oil [l] | 0.5 | 1 | 1 | 0.5 | 1 | 1 |
filling compressor with oil | 1.18 (E) / 1.8 (H) | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 |
type of oil | Emkarate RL 32 3MAF | |||||
coolant tank [l] | 10 | 15 | 25 | 10 | 15 | 15 |
PS working pressure | 29 | |||||
safety valve [bar] | 29 |
*) available only for the MC10 / MCP10
**) only for refrigerating inverter uits.